AMS220 Technical Specifications
   Voltage-to-current conversion ranges   0.001, 0.01, 0.1, 1 and 10 [mA/V]
  Control voltage (VREF) input range (ac/dc)   0 ÷ 3.6 V (rms) / -5 V ÷ +5 V (dc)
  Input resistance of the control voltage input   100 kΩ
  Maximum output current ac/dc   36 mA (rms) / ±50 mA (dc)
  Accuracy of the voltage-to-current conversion (DC)   0.08 %
  Temperature drift   50 ppm/°C
   Operating modes   ACTIVE CMR / ENABLED
  
(active common mode voltage rejection is activated)

  ACTIVE CMR / DISABLED
 
 (current output IB is grounded) 
   Targeted frequency range for ACTIVE CMR / DISABLED 
   operation mode
 DC - 20 kHz (DC - 2 kHz for 1 μA/V range) 
   Targeted frequency range for ACTIVE CMR / ENABLED
   operation mode
  DC-200 Hz
   Operating voltage swing on the current output IA
   against the reference ground (typ.)
  up to ±[6.5 V - |VREF/2|] (± 0.3 V)
   Operating voltage swing on the current output IB
   against the reference ground (typ.)
  up to ±6.6 V (± 0.3 V)
   Operating range of voltage differences
   on the current outputs IA, IB (typ.)
  up to ±13.4 V
   Maximum voltage at the current outputs
   (against the reference ground)
  ±10 V
   Maximum voltage difference on the current outputs   ±20 V
   Power supply   12 V (ac) / 50-60 Hz
   Maximum power input    7 W
   Dimensions (W x H x L)   158 mm x 120 mm x 230 mm
   Weight   2.3 kg
Specifications are subject to change without notice. 